Air conditioner repair in Lake City, FL, could cost a lot of money if minor repairs are not done on time. However, you can try troubleshooting your system before calling a professional. Many times, the issue may be easy to solve.
3 Simple AC repair Tips
Before calling an expert for AC repair in Lake City, FL, homeowners are advised to try these suggestions. Naturally, some aspects of your air conditioner repair will require an experienced and skilled service provider. Professionals must handle things like adding freon or electrical repairs. Some simple tips are:
Thermostat Calibration Issue
If you’re still using the dial-type thermostats of the past and they’re not properly calibrated, it could mean that your air conditioner doesn’t receive proper commands from your control unit. This issue is relatively simple to fix by replacing or calibrating your thermostats.
If you’ve got new programmable thermostats, they may be programmed incorrectly. If you are using the original manual, review the instructions to ensure that your thermostat settings are correct.
Replace Or Clean The Air Filter
The air filter defines the amount of air that enters the home. If your air conditioner isn’t cooling as well as it did in the past, the filter could be dirty and blocked. This blockage affects the flow of air and can make the airflow freeze up, affecting your system’s cooling performance.
This problem can be avoided by regular cleaning or replacement of filters. There is no need for specialized expertise to set up new filters. You can perform this yourself. Make sure the filters you’re about to purchase are top-quality, durable, and long-lasting.
Our AC repair experts in Lake City, FL, generally recommend renewal of the air filter every 60-90 days. The AC unit will cool faster and stop dirt and other allergens from contaminating your air.
Cleaning The Evaporator Coil
The evaporator of the central air system is situated just above the furnace in the plenum. The evaporator might remain hidden; however, it should be cleaned yearly. If the plenum is a sealed metal sheet, Do not try to unzip it. If the plenum is wrapped in foil insulation in its front, you can clean the evaporator.
Take off the foil-wrapped insulation in front of the plenum. Be careful when removing the tape, as you’ll need to replace it in the future. The insulation behind it is an access plate secured by several screws. Take the screws off and remove the plate. Clean the underside of the evaporator unit using a stiff brush.
Clean the tray under the evaporator unit. The tray is used to remove condensation from the evaporator. Set the unit back up, reinstall the plate and restart the air conditioner.
If you’re not in a position to tackle it on your own or have tried the troubleshooting or repair procedures but have not been able to fix your AC, contact the professionals at Lane Heating and Air. Call us at (386) 466-7514 or email us to book an appointment for air conditioner repair in Lake City, FL.